Arsenic Drinking Water Standard
The US EPA maximum contaminant level for arsenic in public drinking water is 0.010 mg/L, equal to 10 µg/L or 10 ppb. The maximum contaminant level (MCL) is an enforceable standard under the Safe Drinking Water Act. EPA’s health-based goal for arsenic, the maximum contaminant level goal (MCLG), is zero, but that goal is not enforceable. The federal arsenic standard applies to community water systems and non-transient non-community water systems, which must monitor for arsenic and, where needed, treat their water to stay in compliance.
US Arsenic Drinking Water Standard at a Glance
| Item | Current US requirement |
|---|---|
| Arsenic MCL | 0.010 mg/L |
| Equivalent | 10 µg/L or 10 ppb |
| MCLG | Zero (non-enforceable goal) |
| Regulator | US Environmental Protection Agency, with states administering most programs |
| Applies to | Community water systems and non-transient non-community water systems |
| Compliance basis | Running annual average at each sampling point |
| Reporting precision | Results reported to the nearest 0.001 mg/L |
| Regulatory basis | Safe Drinking Water Act; National Primary Drinking Water Regulations (40 CFR Part 141) |
| In effect since | January 23, 2006 (replacing the former 0.05 mg/L standard) |
What Is the Maximum Contaminant Level for Arsenic?
The maximum contaminant level for arsenic is 0.010 mg/L. An MCL is the highest level of a contaminant allowed in drinking water delivered by a regulated public water system, and it is legally enforceable.
The arsenic MCL applies to total arsenic. It does not set separate limits for different forms of arsenic. Arsenic results are reported to the nearest 0.001 mg/L, so a result of 0.011 mg/L is above the MCL while 0.010 mg/L is at it.
What Is the Difference Between the Arsenic MCL and MCLG?
The arsenic MCL is the enforceable limit of 0.010 mg/L. The arsenic MCLG is a non-enforceable public health goal set at zero.
EPA sets an MCLG at the level where no known or anticipated health effects would occur, with a margin of safety. For contaminants like arsenic, that goal is zero. The MCL is the enforceable level set after considering treatment feasibility and cost; for arsenic, EPA set the MCL at 0.010 mg/L after weighing costs and benefits. A zero MCLG does not mean public water systems are legally required to reach zero arsenic; they are required to meet the MCL.
What Does 10 ppb of Arsenic Mean?
10 ppb = 10 µg/L = 0.010 mg/L
For dilute aqueous solutions such as drinking water, 1 ppb is treated as equivalent to 1 µg/L, because a liter of water has a mass of about one kilogram. On the same basis, 0.010 mg/L corresponds to 0.010 ppm.
Which Water Systems Must Meet the Arsenic Standard?
The federal arsenic standard applies to community water systems and non-transient non-community water systems. Together these cover the public water systems that serve the same people over extended periods.
Community Water Systems
A community water system serves at least 15 service connections used by year-round residents or regularly serves at least 25 year-round residents. Municipal utilities, rural water districts, and mobile home parks are typical examples.
Non-Transient Non-Community Water Systems
A non-transient non-community water system is not a community system but regularly serves at least 25 of the same people for more than six months a year. Schools, factories, and office buildings with their own water supply are typical examples.
Transient non-community water systems, such as campgrounds or highway rest stops with their own wells, are not subject to the arsenic MCL under the federal rule.
Does the EPA Arsenic Standard Apply to Private Wells?
No. The federal arsenic MCL applies to regulated public water systems, not to private household wells. Private well owners are responsible for testing and treating their own water.
Many state and local health agencies recommend that private well owners test for arsenic and use the federal 10 ppb standard as a guide. Testing should be done through a state-certified or accredited laboratory. State or local health departments can advise on testing frequency and treatment options.
How Is Compliance with the Arsenic MCL Determined?
Compliance with the arsenic MCL is determined at each sampling point, typically each entry point to the distribution system, and is based on a running annual average of results once a system is monitoring quarterly. A single result above 0.010 mg/L is an exceedance that triggers quarterly monitoring; on its own, it is a violation only if it is high enough to push the running annual average above the MCL.
In general terms:
- Samples are collected at each entry point to the distribution system and analyzed by a certified laboratory using an approved method.
- A result above the MCL generally triggers increased, quarterly monitoring at that sampling point. The state may also require a confirmation sample within two weeks, which is averaged with the initial result.
- Compliance is then evaluated on the running annual average of quarterly results. If the average at a sampling point exceeds 0.010 mg/L, the system is in violation.
- For a system that was monitoring annually or less often, the initial exceedance (averaged with any confirmation sample) counts as the first quarterly sample of the running annual average. A result above 0.040 mg/L, four times the MCL, therefore puts the system out of compliance immediately. More generally, any result high enough that the annual average must exceed the MCL is an immediate violation. Results below the method detection limit count as zero.
State primacy agencies administer most of these details, including confirmation samples, waivers, and when quarterly monitoring can be reduced. Systems should confirm exact requirements with their state drinking water program.
How Often Are Public Water Systems Tested for Arsenic?
Arsenic monitoring frequency depends on the source type, past results, waivers, and state requirements. Under the federal baseline, groundwater systems sample each sampling point once per three-year compliance period, and surface water systems sample annually.
States can grant waivers that reduce monitoring for systems with a history of results below the MCL, and they can also require more frequent monitoring. Where a result exceeds the MCL, monitoring generally increases to quarterly at that sampling point until the state determines the system is reliably and consistently below the MCL. New systems and new sources must demonstrate compliance within a period set by the state.
What Happens If Drinking Water Exceeds the Arsenic Standard?
When arsenic exceeds 10 ppb in a public water system, the first consequence is usually increased monitoring, not an automatic violation. A violation occurs when the compliance calculation, typically the running annual average, exceeds the MCL.
If a system violates the MCL, it must report to the state and notify customers under EPA’s public notification rules. Corrective actions typically include treatment changes, new or optimized treatment, operational changes, blending with lower-arsenic sources, developing a new source, or connecting to another system. The state primacy agency plays the central role in deciding what actions and schedules are required.
Why Is Arsenic Regulated in Drinking Water?
Arsenic is regulated because long-term exposure above the standard is associated with health concerns. EPA’s required health effects language states that some people who drink water containing arsenic in excess of the MCL over many years could experience skin damage or problems with their circulatory system, and may have an increased risk of getting cancer.
The standard addresses long-term exposure to inorganic arsenic, which is the predominant form in most drinking water sources. Questions about personal health should go to a medical professional.
Does the Arsenic Standard Apply to As(III) and As(V)?
The arsenic MCL is based on total arsenic. There are no separate federal limits for As(III) (arsenite) and As(V) (arsenate); both count toward the 0.010 mg/L standard.
Speciation still matters for treatment. As(III) and As(V) behave differently in removal processes, and many methods remove As(V) more readily, so water with significant As(III) is often oxidized before treatment. For details, see arsenic III vs. arsenic V.
How Is Drinking Water Tested for Arsenic?
Public water systems must have arsenic samples analyzed by a laboratory certified by EPA or the state, using an EPA-approved analytical method. Private well owners should use a state-certified or accredited laboratory.
Arsenic has no taste, odor, or color at the levels found in drinking water, so laboratory testing is the only reliable way to know whether it is present. Treatment decisions should be based on actual test results, ideally from more than one sample, because arsenic levels can vary over time.
Can State Arsenic Standards Be Stricter Than the Federal Standard?
Yes. To administer drinking water programs, states must adopt drinking water regulations that are no less stringent than the federal National Primary Drinking Water Regulations (40 CFR 142.10), and they may adopt stricter limits or additional requirements. Water systems should check with their state drinking water program for the standard and monitoring requirements that apply to them.
Is the Arsenic Drinking Water Standard the Same in Every Country?
No. Drinking water standards vary by jurisdiction. This page covers the US federal standard. Projects outside the United States should follow the regulations of the country or region where the water will be used.
What Should a Water System Do If Arsenic Is Above the Target?
A water system with arsenic near or above 10 ppb typically works through a treatment evaluation alongside its regulatory obligations. A practical sequence:
- Confirm and characterize the water. Confirm the result and collect a broader water analysis, including pH, silica, phosphate, sulfate, iron, and manganese.
- Review concentration and variability. Look at historical results for each source and sampling point.
- Consider speciation. Determine whether As(III) is significant, especially for groundwater.
- Evaluate existing treatment. Modifying an existing process, such as iron removal or coagulation, is often simpler and cheaper than adding new treatment.
- Compare treatment options. Match methods to the water chemistry, system size, and operating resources.
- Pilot or test where appropriate. Column or pilot testing on the actual water confirms performance.
- Implement treatment and monitoring. Plan for ongoing arsenic monitoring after treatment.
- Coordinate with the state. The state primacy agency sets compliance requirements and often reviews treatment plans.
This is a treatment planning sequence, not legal or regulatory advice.
Treatment Options for Meeting the Arsenic Standard
Established treatment options for meeting the arsenic standard include adsorptive media, coagulation/filtration, oxidation/filtration, ion exchange, reverse osmosis, and, at plants that already soften water, modified lime softening. EPA lists several of these as best available technologies and small system compliance technologies for arsenic, and small systems may also use point-of-use devices under specific conditions.
The right choice depends on source water chemistry, arsenic concentration and speciation, pH, competing constituents, system size, operator resources, and lifecycle cost. For a detailed comparison, see arsenic removal methods.
Adsorptive Media for Arsenic Compliance
Adsorptive media can reduce arsenic in suitable water treatment applications, particularly groundwater wells and small and medium-sized systems. Water passes through a fixed bed of granular media that binds dissolved arsenic, and the media is replaced when its capacity is used up.
Media suitability depends on water chemistry, including pH, speciation, silica, and phosphate. Systems using adsorptive media need regular arsenic monitoring to detect breakthrough and a plan for media changeout. Public water systems should use media certified for drinking water contact. Media alone does not guarantee compliance; design, operation, and monitoring all matter. For media types and selection, see arsenic adsorption media.
NXT® for Arsenic Removal in Drinking Water
NXT® is a granular iron hydroxide arsenic adsorption media from Treibacher Industrie AG, used in drinking water treatment including at small and medium-sized waterworks. Treibacher states that NXT® functions over a wide pH range and provides stable arsenic binding, and the media has a specific surface area greater than 230 m²/g.
For product details, see NXT® arsenic removal media.
Frequently Asked Questions About the Arsenic Drinking Water Standard
What is the acceptable level of arsenic in drinking water?
For US public water systems, the enforceable limit is 0.010 mg/L (10 µg/L or 10 ppb), set by the US EPA as the maximum contaminant level for arsenic.
What is the EPA arsenic limit in drinking water?
The EPA arsenic limit is 0.010 mg/L, or 10 parts per billion. It applies to community water systems and non-transient non-community water systems.
Is 10 ppb arsenic safe or legal?
Ten ppb is the federal enforceable limit for regulated public water systems, so a system at or below it is meeting the arsenic MCL. It is a regulatory standard, not a statement that any level is risk-free; EPA’s health-based goal for arsenic is zero.
What is the arsenic MCL?
The arsenic maximum contaminant level is 0.010 mg/L, enforceable under the Safe Drinking Water Act since January 23, 2006.
What is the arsenic MCLG?
The arsenic maximum contaminant level goal is zero. It is a non-enforceable health goal; public water systems must meet the MCL, not the MCLG.
Does the arsenic standard apply to private wells?
No. The federal arsenic MCL applies to regulated public water systems. Private well owners are responsible for testing and treating their own water, and many state health agencies recommend using the 10 ppb standard as a guide.
How can I test water for arsenic?
Use a state-certified or accredited laboratory. Arsenic cannot be detected by taste, smell, or appearance. Public water systems must use certified laboratories and approved methods for compliance samples.
What happens if arsenic exceeds 10 ppb?
For a public water system, a result above 10 ppb generally triggers increased monitoring. A violation occurs when the compliance calculation, usually the running annual average, exceeds the MCL, at which point the system must notify the state and its customers and take corrective action.
Can arsenic be removed from drinking water?
Yes. Adsorptive media, coagulation/filtration, oxidation/filtration, ion exchange, and reverse osmosis can all remove arsenic, depending on the water. See arsenic removal from drinking water.
What treatment methods remove arsenic?
The main methods are adsorptive media, coagulation/filtration, oxidation/filtration, ion exchange, and reverse osmosis. The best choice depends on water chemistry, system size, and operating resources. See arsenic treatment technologies.
Discuss Your Arsenic Treatment Application
If a drinking water source needs arsenic treatment, Treibacher can provide information on NXT® and adsorptive media for arsenic removal. Public water systems, utilities, consulting engineers, water treatment companies, OEMs, and filter manufacturers can contact Treibacher to discuss their application. Treibacher does not provide regulatory or legal compliance advice; compliance questions should go to the relevant state drinking water program.
Explore NXT® Arsenic Removal MediaContact Treibacher About Arsenic Removal